SST — System Service Tools
Команда для входа:
STRSST
System Service Tools (SST) Select one of the following: 1. Start a service tool 2. Work with active service tools 3. Work with disk units 4. Work with diskette data recovery 5. Work with system partitions 6. Work with system capacity 7. Work with system security 8. Work with service tools user IDs Selection F3=Exit F10=Command entry F12=Cancel
В основном меню выбрать 3. Work with disk units
и клавишу Enter
Work with Disk Units Select one of the following: 1. Display disk configuration 2. Work with disk configuration 3. Work with disk unit recovery Selection F3=Exit F12=Cancel
Нажать 1. Display disk configuration
и клавишу Enter
Display Disk Configuration Select one of the following: 1. Display disk configuration status 2. Display disk configuration capacity 3. Display disk configuration protection 4. Display non-configured units 5. Display device parity status 6. Display disk hardware status 7. Display disk compression status Selection F3=Exit F12=Cancel
Нажать 6. Display disk hardware status
и клавишу Enter
Display Disk Hardware Status Serial Resource Hardware ASP Unit Number Type Model Name Status 1 1 21-D0001 4326 050 DD006 Operational 1 1 21-E0002 4326 050 DD003 Operational 1 5 21-E0003 4326 050 DD001 Operational 1 5 21-E0004 4326 050 DD002 Operational 1 6 21-E0005 4326 050 DD004 Operational 1 6 21-B0006 4326 050 DD007 Operational Press Enter to continue. F3=Exit F5=Refresh F9=Display disk unit details F11=Display disk compression status F12=Cancel
Нажать F9=Display disk unit details
Display Disk Units Type option, press Enter. 5=Display hardware resource information details Serial Resource OPT ASP Unit Number Type Model Name Status 1 1 21-D0001 4326 050 DD006 Active 1 1 21-E0002 4326 050 DD003 Suspended 1 5 21-E0003 4326 050 DD001 Active 1 5 21-E0004 4326 050 DD002 Active 1 6 21-E0005 4326 050 DD004 Active 1 6 21-B0006 4326 050 DD007 Active
Выбрать опцию 5 для нужного диска и клавишу Enter
Disk Unit Hardware Resource Information Details Type. . . . . . . . . . . . : 4326 Model . . . . . . . . . . . : 050 Level . . . . . . . . . . . : 2 Serial Number . . . . . . . : 21-E0002 Resource Name . . . . . . . : DD003 Physical location: Frame ID . . . . . . . . . : 1 Card position. . . . . . . : D04 Device position. . . . . . :
Значение Card position
это и есть позиция диска.
В основном меню выбрать 3. Work with Disk Unit Recovery
Work with Disk Unit Recovery Select one of the following: 1. Replace configured unit 2. Disk unit problem recovery procedures 3. Suspend mirrored protection 4. Resume mirrored protection 5. Delete disk unit data 6. Rebuild disk unit data 7. Reclaim IOP cache storage
3. Suspend mirrored protection
Suspend Mirrored Protection Type option, press Enter. 1=Suspend Mirrored Protection Serial Resource OPT Unit ASP Number Type Model Name Status 1 1 21-D0001 4326 050 DD006 Active 1 1 68-00002 4326 050 DD005 Active 5 1 21-00003 4326 050 DD001 Active 5 1 21-00004 4326 050 DD002 Active 6 1 21-00005 4326 050 DD004 Active 6 1 21-00006 4326 050 DD007 Active
Выбрать нужный диск.